MATERIAL SAFETY
DATA SHEETS
VESCONITE
VESCONITE HILUBE
MATERIAL SAFETY
DATA SHEET
VESCONITE
|
Product
Information |
Product identifier:
Product use: |
Vesconite
Plain bearing and bushing material |
| Manufacturer
name and address |
Virginia Engineering Services
(Pty) Ltd |
|
|
P O Box 47
Virginia
South Africa
9430
Tel no. +27 (57) 212 0000
Fax no. +27 (57) 212 3355
|
| |
|
Hazards
Identification |
| Ingredients are
not considered a health hazard under current legislation |
| |
|
Physical
Data |
|
Physical state: |
Solid, non metallic |
|
Appearance: |
Grey black |
|
Odour: |
None |
|
Odour threshold: |
Not Applicable |
|
Specific gravity: |
1.38 |
|
Vapour pressure: |
Not Applicable |
|
Vapour density: |
N/A |
|
Evaporation rate: |
N/A |
|
Melting point: |
260oC / 500oF |
|
Freezing point: |
N/A |
|
pH: |
N/A |
|
Solubility in water: |
Non-soluble |
|
Percent volatiles: |
None |
| |
|
Handling
and Storage |
|
General information: |
No special protective measures required |
|
Precautions against fire and explosion:
|
No special precautions against fire and
explosion required |
| |
|
Fire and
Emergency Response Data |
|
Conditions of flammability: |
Can be made to burn with difficulty by
persistent application of a flame |
|
Flashpoint: |
Not Applicable |
|
Upper flammable limit: |
N/A |
|
Lower flammable limit: |
N/A |
|
Auto-ignition temperature: |
510oC |
|
Explosion data sensitivity to
mechanical impact:
to static discharge:
|
N/A
N/A |
|
Extinguishing media:
|
All generally used extinguishing media
may be used: water; dry chemical; foam; carbon dioxide or sand |
|
Extinguishing media which must not
be used for safety reasons:
|
Not known according to previous
experience. |
|
Special procedures:
|
Evacuate all non emergency personnel to a
safe area. Fire fighters should use self contained breathing apparatus.
Avoid breathing smoke, fumes and decomposition products. Use water spray
to quench smouldering materials. Burning produces intense heat, toxic
gases and dense smoke. |
| |
|
Reactivity
Data |
|
Stability:
|
Stable, no known conditions to avoid. If
stored and handled in accordance with standard industrial practices, no
hazardous reactions are known. |
|
Incompatibility: |
Not Applicable |
|
Hazardous decomposition products:
|
Decomposition begins above 250oC,
but at this temperature fumes are innocuous. Above 300oC more
complex breakdown occurs and the resulting fumes are irritants. Carbon
monoxide (CO), carbon dioxide (CO2) and low molecular weight
compounds under certain conditions. |
|
Hazardous polymerisation: |
Will not occur |
| |
| Toxicological
Properties |
|
Exposure limits: |
N/A |
|
Skin contact: |
N/A |
|
Skin absorption: |
N/A |
|
Eye contact:
|
In the form of shavings or dust only.
Abrasion hazard from machining or grinding |
|
Inhalation: |
N/A |
|
General information:
|
According to present experience, the
material is physiologically compatible and is neither mutagenic,
carcinogenic or teratogenic. |
|
Accute toxicity: |
No data known |
| |
|
Preventive
Measures |
|
Respiratory protection:
|
No special precautions necessary. When
grinding use a dust mask, as material will produce a nuisance dust if no
coolant or extraction equipment is used |
|
Ventilation: |
As required to avoid nuisance dust |
|
Long term EL (8 hrs): |
No standard |
|
Protective gloves: |
N/A |
|
Eye protection: |
Protective glasses if grinding or
machining |
|
Other protective equipment: |
N/A |
|
Handling precautions: |
N/A |
|
Spills: |
N/A |
|
Waste disposal:
|
Dispose as solid waste according to local
laws |
| |
|
First Aid
Measures |
|
Swallowing: |
No special measures necessary. Give water
to drink. |
|
Skin:
|
It is good personal hygiene practice to
wash hands after handling. |
|
Inhalation: |
No special precautions are necessary.
Avoid inhalation of dust and decomposition products by use of adequate
ventilation. If coughing or other respiratory symptoms occur, the person
should seek fresh air and if they persist, see a physician. |
|
Eyes:
|
Flush or remove dust particles as with
any other non hazardous substances. Continue to rinse for at least 15
minutes and obtain medical attention in case of continuous irritation. |
| |
|
Management
Data |
|
Prepared by: |
Dr J-P Leger |
|
Telephone no.: |
+27 (57) 212 0000 |
|
Preparation date: |
12 April 2001 |
All information contained in this material safety
data sheet has been prepared from information supplied by the primary chemical
producers or suppliers to Virginia Engineering Services (Pty) Ltd. This
information is supplied free of charge and is based on technical data believed
to be correct and reliable. It is intended for the use of persons having
technical skills at their own discretion.
Information contained herein is given with the
understanding that those using it will satisfy themselves that their particular
conditions of use present no health or safety hazards. Since conditions of use
are outside the control of the manufacturer, the manufacturer and its agents
make no warranties expressed or implied, and assume no liability in connection
with any use of this information.
MATERIAL SAFETY DATA SHEET
VESCONITE HILUBE
Product Information
|
Product identifier: |
Vesconite
Hilube |
| Product use: |
Plain bearing
and bushing material |
|
Manufacturer name and address |
Virginia Engineering Services (Pty) Ltd |
| |
P O
Box 47 |
| |
Virginia |
| |
South Africa |
| |
9430 |
|
Tel
no. +27 (57) 212 0000 |
| |
Fax
no. +27 (57) 212 3355 |
Hazards Identification
Ingredients are not considered a health hazard under
current legislation
|
Physical Data |
|
| Physical state: |
Solid, non
metallic |
| Appearance: |
White |
| Odour: |
None |
| Odour threshold: |
Not Applicable |
| Specific
gravity: |
1.38 |
| Vapour pressure: |
Not Applicable |
| Vapour density: |
N/A |
| Evaporation
rate: |
N/A |
| Melting point: |
260°C |
| Freezing point: |
N/A |
| pH: |
N/A |
| Solubility in
water: |
Non-soluble |
| Percent
volatiles: |
None |
MATERIAL SAFETY
DATA SHEET VESCONITE HILUBE
|
Handling and Storage |
|
| General
information: |
No special
protective measures required |
| Precautions
against fire and explosion: |
No special
precautions against fire and explosion required |
|
Fire and Emergency Response
Data |
|
Conditions of flammability: |
Can
be made to burn with difficulty by persistent application of a flame |
|
Flashpoint: |
Not
Applicable |
|
Upper flammable limit: |
N/A |
|
Lower flammable limit: |
N/A |
|
Auto-ignition temperature: |
510°C |
|
Explosion data sensitivity |
|
|
to mechanical impact: |
N/A |
| to
static discharge: |
N/A |
|
Extinguishing media: |
All
generally used extinguishing media may be used: water; dry chemical; foam;
carbon dioxide or sand |
|
Extinguishing media which must not be used for safety reasons: |
Not
known according to previous experience. |
|
Special procedures: |
Evacuate all non emergency personnel to a safe area.
Fire fighters must use self contained breathing
apparatus. Avoid breathing smoke, fumes and
decomposition products. Use water spray to quench
smouldering materials. Burning produces intense
heat, toxic gases and dense smoke. |
|
Reactivity Data |
|
| Stability: |
Stable, no known
conditions to avoid. If stored and handled in accordance with standard
industrial practices, no hazardous reactions are known. |
| Incompatibility: |
Not Applicable |
|
Hazardous decomposition products: |
Decomposition
begins above 250°C, but at this temperature fumes are innocuous. Above 380°C
more complex breakdown occurs and the resulting fumes may include carbon
monoxide (CO), carbon dioxide (CO2), low molecular weight
compounds and a small proportion of toxic and corrosive products, depending
on the conditions of combustion. |
| Hazardous
polymerisation: |
Not know to
occur |
MATERIAL SAFETY DATA SHEET VESCONITE HILUBE
|
Toxicological Properties |
|
| Exposure limits: |
N/A |
| Skin contact: |
N/A |
| Skin absorption: |
N/A |
| Eye contact:
|
In the form of
shavings or dust only. Abrasion hazard from machining or grinding |
| Inhalation: |
N/A |
| General
information: |
According to
present experience, the material is physiologically compatible and is
neither mutagenic, carcinogenic or teratogenic. |
|
Accute toxicity: |
No data known |
| Preventive
Measures |
|
| Respiratory
protection: |
No special
precautions necessary. When grinding use a dust mask, as material will
produce a nuisance dust if no coolant or extraction equipment is used |
| Ventilation: |
As required to
avoid nuisance dust |
| Long term EL (8
hrs): |
No standard |
| Protective
gloves: |
N/A |
| Eye protection: |
Protective
glasses if grinding or machining |
| Other protective
equipment: |
N/A |
| Handling
precautions: |
N/A |
| Spills: |
N/A |
| Waste disposal: |
Dispose as solid
waste according to local laws. Do not incinerate. |
| General: |
Contamination of tobacco smoking materials, for example
by shavings or dust, should be avoided |
MATERIAL SAFETY DATA SHEET VESCONITE HILUBE
|
First Aid Measures |
|
Ingestion: |
Non
hazardous by ingestion. No special measures necessary. Give water to drink. |
| Skin: |
It is good personal hygiene practice to wash hands after
handling. |
|
Inhalation: |
No
special precautions are necessary. Avoid inhalation of dust by use of
adequate ventilation. If coughing or other respiratory symptoms occur, the
person should seek fresh air and if they persist, see a physician. |
|
Inhalation of fumes: |
Thermal decomposition at temperatures >380°C yields a range of toxic
products, depending on the conditions of combustion. Exposure to these
combustion products must be avoided. Remove from exposure to fresh air, rest
and keep warm. Medical attention recommended. Symptomatic treatment
indicated. |
|
Eyes: |
Flush or remove dust particles as with any other non hazardous substances.
Continue to rinse for at least 15 minutes and obtain medical attention in
case of continuous irritation. |
|
Management Data |
|
| Prepared by: |
Dr J-P Leger |
| Telephone no.: |
+27 (57) 212 0000 |
|
Preparation date: |
12 April 2001 |
All information contained in this material safety data sheet
has been prepared from information supplied by the primary chemical producers or
suppliers to Virginia Engineering Services (Pty)
Ltd. This information is supplied free of charge and is based on technical data
believed to be correct and reliable. It is intended for the use of persons
having technical skills at their own discretion.
Information contained herein is given with the
understanding that those using it will satisfy themselves that their particular
conditions of use present no health or safety hazards. Since conditions of use
are outside the control of the manufacturer, the manufacturer and its agents
make no warranties expressed or implied, and assume no liability in connection
with any use of this information.
Updated Oct 10 2005
|